Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.420
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577923

RESUMO

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Assuntos
Dissecção Aórtica , Insuficiência da Valva Aórtica , Valva Aórtica , Implante de Prótese Vascular , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Dissecção Aórtica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Pessoa de Meia-Idade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Desenho de Prótese , Prótese Vascular , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Aortografia
2.
J Cardiothorac Surg ; 19(1): 237, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627730

RESUMO

Redo ascending and aortic arch surgeries following previous cardiac or aortic surgery are associated with high risk of morbidity and mortality due to multiple factors included sternal re-entry injury, extensive aortic arch surgery, emergency aortic surgery, prolonged cardiopulmonary bypass duration, poor heart function, and patients with older age. Therefore, appropriate surgical strategies are important. We report a case of a 72-year-old gentleman with previous surgery of aortic root replacement who presented with acute Type A aortic dissecting aneurysm of ascending and aortic arch complicated with left hemothorax, which was successfully treated by emergency redo aortic surgery with frozen elephant trunk (FET) technique.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Masculino , Humanos , Idoso , Aorta Torácica/cirurgia , Prótese Vascular , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Valva Aórtica/cirurgia , Dissecção Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Stents
3.
J Cardiothorac Surg ; 19(1): 239, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632653

RESUMO

OBJECTIVES: Aortic pathologies often present with elevated inflammatory biomarkers due to the nature of the disease. Open aortic surgery causes significant trauma to the body due to often mandatory ischemic periods, long cardiopulmonary bypass times and polytransfusion. We aim to determine postoperative trends on inflammation biomarkers for different aortic pathologies and type of surgery in different segments of the aorta. METHODS: Retrospective review of prospectively collected data of 193 consecutive patients who underwent aortic surgery in our centre between 2017 and 2021, grouped according to the type of aortic intervention: (1) Type A aortic dissection (AD) repair with ascending aorta/hemiarch replacement, (2) Aortic root replacement (ARR), (3) Aortic arch + Frozen elephant trunk (FET), (4) Descending thoracic aorta (DTA)/Thoraco-Abdominal aortic repair (TAA). Primary outcomes were daily values of white blood cells (WBC) and C-Reactive Protein (CRP) during the first 15 postoperative days. RESULTS: All groups had a similar inflammatory peak in the first 2-4 days (WBC 12-15 × 109 c/L). AD and FET groups show similar trends with WBC and CRP peaks on days 2 and 10. The ARR group didn't experience the 2nd peak as most patients were already discharged. DTA/TAA patients experienced a more prolonged inflammatory response, reaching a plateau by day 5-10. AD group shows the highest WBC levels and the DTA/TAAA group the highest CRP levels. CRP levels remain elevated (100-200 mg/L) in all groups after 15 postoperative days. CONCLUSIONS: Inflammatory biomarkers show different postoperative trends depending on the clinical presentation and complexity of the aortic procedure performed. Further understanding of the inflammatory response to different aortic pathologies and surgical procedures will permit reduction on the liberal use of antibiotics that this cohort of patients are usually exposed to. An earlier version of the data included in this manuscript was presented as Oral Abstract in the UK Society of Cardiothoracic Surgery Annual meeting in 2021.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Humanos , Implante de Prótese Vascular/métodos , Aorta/cirurgia , Aorta Torácica/cirurgia , Estudos Retrospectivos , Inflamação , Biomarcadores , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Prótese Vascular
4.
Medicine (Baltimore) ; 103(14): e37731, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38579061

RESUMO

RATIONALE: A hostile iliac access route is an important consideration when enforcing endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA). Herein, we report a case of AAA with unilateral external iliac artery occlusion, for which bifurcated EVAR was successfully performed using a single femoral and brachial artery access. PATIENT CONCERNS: A 76-year-old man who had undergone surgery for lung cancer 4.5 years prior was diagnosed AAA by computed tomography (CT). DIAGNOSIS: Two and a half years before presentation, CT revealed an infrarenal 48 mm AAA, which had enlarged to 57 mm by 2 months preoperatively. CT identified occlusion from the right external iliac artery to the right common femoral artery, with no observed ischemic symptoms in his right leg. The right external iliac artery, occluded and atrophied, had a 1 to 2 mm diameter. INTERVENTION: Surgery was commenced with the selection of a Zenith endovascular graft (Cook Medical) with an extended body length. Two Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associate) were delivered from the right axilla as the contralateral leg. OUTCOMES: CT scan on the 2nd day after surgery revealed no endoleaks. LESSONS: While the long-term results remain uncertain, this method may serve as an option for EVAR in patients with unilateral external iliac artery occlusion.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Masculino , Humanos , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/métodos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Axila/cirurgia , Perna (Membro)/cirurgia , Procedimentos Endovasculares/métodos , Stents , Resultado do Tratamento , Aneurisma Ilíaco/cirurgia
5.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38569918

RESUMO

OBJECTIVES: Our goal was to access early and mid-term outcomes of a gutter-plugging chimney stent graft for treatment of Stanford type B aortic dissections in the clinical trial Prospective Study for Aortic Arch Therapy with stENt-graft for Chimney technology (PATENCY). METHODS: Between October 2018 and March 2022, patients with Stanford type B aortic dissections were treated with the Longuette chimney stent graft in 26 vascular centres. The efficiency and the incidence of adverse events over 12 months were investigated. RESULTS: A total of 150 patients were included. The technical success rate was 99.33% (149/150). The incidence of immediate postoperative endoleak was 5.33% (8/150, type I, n = 6; type II, n = 1; type IV, n = 1) neurologic complications (stroke or spinal cord ischaemia); the 30-day mortality was 0.67% (1/150) and 1.33% (2/150), respectively. During the follow-up period, the median follow-up time was 11.67 (5-16) months. The patent rate of the Longuette graft was 97.87%. Two patients with type I endoleak underwent reintervention. The follow-up rate of the incidence of retrograde A type aortic dissection was 0.67% (1/150). There was no paraplegia, left arm ischaemia or stent migration. CONCLUSIONS: For revascularization of the left subclavian artery, the Longuette chimney stent graft can provide an easily manipulated, safe and effective endovascular treatment. It should be considered a more efficient technique to prevent type Ia endoleak. Longer follow-up and a larger cohort are needed to validate these results. CLINICAL TRIAL REGISTRY NUMBER: NCT03767777.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Stents , Humanos , Dissecção Aórtica/cirurgia , Masculino , Estudos Prospectivos , Feminino , Pessoa de Meia-Idade , Stents/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/instrumentação , Idoso , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Resultado do Tratamento , Desenho de Prótese , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Adulto
6.
Arterioscler Thromb Vasc Biol ; 44(5): 1065-1085, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38572650

RESUMO

Blood vessels are subjected to complex biomechanical loads, primarily from pressure-driven blood flow. Abnormal loading associated with vascular grafts, arising from altered hemodynamics or wall mechanics, can cause acute and progressive vascular failure and end-organ dysfunction. Perturbations to mechanobiological stimuli experienced by vascular cells contribute to remodeling of the vascular wall via activation of mechanosensitive signaling pathways and subsequent changes in gene expression and associated turnover of cells and extracellular matrix. In this review, we outline experimental and computational tools used to quantify metrics of biomechanical loading in vascular grafts and highlight those that show potential in predicting graft failure for diverse disease contexts. We include metrics derived from both fluid and solid mechanics that drive feedback loops between mechanobiological processes and changes in the biomechanical state that govern the natural history of vascular grafts. As illustrative examples, we consider application-specific coronary artery bypass grafts, peripheral vascular grafts, and tissue-engineered vascular grafts for congenital heart surgery as each of these involves unique circulatory environments, loading magnitudes, and graft materials.


Assuntos
Prótese Vascular , Hemodinâmica , Humanos , Animais , Modelos Cardiovasculares , Falha de Prótese , Estresse Mecânico , Fenômenos Biomecânicos , Mecanotransdução Celular , Implante de Prótese Vascular/efeitos adversos , Desenho de Prótese , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/etiologia , Remodelação Vascular
7.
J Cardiothorac Surg ; 19(1): 199, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600502

RESUMO

BACKGROUND: Total endovascular technique with fenestrated endovascular graft might be hampered for the late dilatation of proximal landing zone, which may cause endografts migration. We describe a successful urgent hybrid procedure for extent III thoracoabdominal aortic aneurysm with aortic intramural hematoma. CASE PRESENTATION: A 55-year-old female with thoracoabdominal aortic aneurysm was considered at high surgical risk and unfit for open repair due to multiple comorbidities. Therefore, a hybrid procedure of surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted Transaortic epicardial fixation of endograft was finally chosen and performed in the endovascular operating room. A 3-port technique was performed through a left video-assisted thoracoscopic approach. After the first tampering stent-graft was deployed, a double-needle suture was penetrated both the aortic wall and stent-graft to fixate it in the proximal descending aorta. Then the second endograft, which had been fenestrated on table, was introduced and oriented extracorporeally by rotating superior mesenteric artery and left renal artery fenestration radiopaque markers and deployed with perfect apposition between the fenestrations and target visceral artery. Each vessel was sequentially stented using Viabahn self-expandable stent to finish target vessel stenting. An Ankura cuff stent was deployed in the distal abdominal aortic artery. CONCLUSION: Surgeon-modified fenestrated endovascular graft combined with thoracoscope-assisted fixation may be an innovative and viable alternative for selected high-risk patients with extent III thoracoabdominal aortic aneurysm. A longer follow-up is needed to ascertain the success of this approach.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Cirurgiões , Feminino , Humanos , Pessoa de Meia-Idade , Prótese Vascular , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Toracoscópios , Resultado do Tratamento , Stents , Procedimentos Endovasculares/métodos , Desenho de Prótese , Aneurisma da Aorta Abdominal/cirurgia
8.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38598445

RESUMO

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Assuntos
Dissecção Aórtica , Implante de Prótese Vascular , Stents , Humanos , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/efeitos adversos , Doença Aguda , Desenho de Prótese , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Aneurisma Aórtico/cirurgia
9.
J Cardiovasc Surg (Torino) ; 65(2): 119-123, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618696

RESUMO

This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Artéria Renal , Stents , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Humanos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Artéria Renal/cirurgia , Artéria Renal/diagnóstico por imagem , Resultado do Tratamento , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Fatores de Risco
10.
J Cardiovasc Surg (Torino) ; 65(2): 124-131, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635285

RESUMO

INTRODUCTION: We performed a systematic review and meta-analysis to assess the existing published evidence regarding the safety and efficacy of the endovascular aortic repair with chimney technique (ch-EVAR) and physician-modified stent-grafts (PMSGs) for the treatment of pararenal aortic aneurysm repair. EVIDENCE ACQUISITION: A systematic search of all relevant studies reported until October 2023 according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines was performed. The pooled 30-day mortality, peri- and postoperative complication rates were estimated using fixed or random effect methods. EVIDENCE SYNTHESIS: A total of 679 study titles were identified by the initial search strategy, of which 16 were considered eligible for inclusion in the meta-analysis. A total of 1094 patients (ch-EVAR N.=861 and PMSG N.=233) (90% male) were identified. The pooled 30-day mortality rate was 3.4% for ch-EVAR and 2.6% for PMSG. The major adverse events (MAE) in the early period was 14.7% for ch-EVAR and 18.5% PMSG, respectively. Higher occlusion rate was observed of the chimney stents grafts (8.2%) than the bridging stents (1.4%) during the follow-up period. CONCLUSIONS: Ch-EVAR and physician-modified technology are safe with low 30-day mortality in elective settings for pararenal aortic aneurysms repair. No significant differences were seen between the two surgical methods regarding the early major adverse events rate. However, higher occlusion rate for the chimneys can be expected over time.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Complicações Pós-Operatórias , Desenho de Prótese , Stents , Humanos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Resultado do Tratamento , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Masculino , Feminino , Idoso , Fatores de Tempo , Medição de Risco , Pessoa de Meia-Idade
11.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635286

RESUMO

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Estudos de Viabilidade , Desenho de Prótese , Stents , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Feminino , Masculino , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Meios de Contraste , Aortografia
13.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635284

RESUMO

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares , Artéria Ilíaca , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Artéria Ilíaca/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Resultado do Tratamento , Fatores de Risco , Prótese Vascular , Complicações Pós-Operatórias/etiologia
14.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635287

RESUMO

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Endoleak , Procedimentos Endovasculares , Desenho de Prótese , Sistema de Registros , Humanos , Masculino , Feminino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Idoso , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Endoleak/etiologia , Fatores de Tempo , Resultado do Tratamento , Idoso de 80 Anos ou mais , Stents , Estudos Retrospectivos , Fatores de Risco , Rotulagem de Produtos , Correção Endovascular de Aneurisma
15.
BMJ Case Rep ; 17(3)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38521516

RESUMO

A patient in his late 30s presented with issues of retrosternal chest pain and palpitations. He had sustained a splinter injury to the left hemithorax a year ago for which he had been managed with a tube thoracostomy. During subsequent evaluations, he was found to have atrial fibrillations and a CT angiography revealed an arch of the aorta pseudoaneurysm with a fistulous communication with the innominate vein, which being a rare condition has no established treatment protocols. Endovascular salvage of the condition required an aortic Ishimaru zone 2 deployment of the thoracic endovascular aortic repair stent graft to provide an adequate landing zone. The elective left subclavian artery revascularisation was obtained by a left carotid artery to left subclavian artery bypass. Post procedure there was complete exclusion of the pseudoaneurysm sac, and the fistulous aorto-venous communication inflow tract. The patient recuperated well and has returned to full active duties.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Traumatismos Torácicos , Humanos , Masculino , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/lesões , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Veias Braquiocefálicas/diagnóstico por imagem , Veias Braquiocefálicas/cirurgia , Desenho de Prótese , Stents , Traumatismos Torácicos/cirurgia , Resultado do Tratamento , Adulto
16.
Nat Commun ; 15(1): 2187, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467617

RESUMO

Advancements in congenital heart surgery have heightened the importance of durable biomaterials for adult survivors. Dystrophic calcification poses a significant risk to the long-term viability of prosthetic biomaterials in these procedures. Herein, we describe the natural history of calcification in the most frequently used vascular conduits, expanded polytetrafluoroethylene grafts. Through a retrospective clinical study and an ovine model, we compare the degree of calcification between tissue-engineered vascular grafts and polytetrafluoroethylene grafts. Results indicate superior durability in tissue-engineered vascular grafts, displaying reduced late-term calcification in both clinical studies (p < 0.001) and animal models (p < 0.0001). Further assessments of graft compliance reveal that tissue-engineered vascular grafts maintain greater compliance (p < 0.0001) and distensibility (p < 0.001) than polytetrafluoroethylene grafts. These properties improve graft hemodynamic performance, as validated through computational fluid dynamics simulations. We demonstrate the promise of tissue engineered vascular grafts, remaining compliant and distensible while resisting long-term calcification, to enhance the long-term success of congenital heart surgeries.


Assuntos
Prótese Vascular , Calcinose , Ovinos , Animais , Estudos Retrospectivos , Calcinose/cirurgia , Materiais Biocompatíveis , Politetrafluoretileno
17.
No Shinkei Geka ; 52(2): 263-269, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38514115

RESUMO

With the advent of high-resolution imaging and advancements in computational fluid dynamics(CFD)and computational structural mechanics(CSM)analyses, clinical simulation of endovascular intervention has gradually become feasible. Virtual stents have become indispensable for coil embolization. For braided stents, such as those with low-profile visualized intraluminal support and flow diverters, predicting postplacement elongation and contraction is challenging; however, software development has enabled more precise treatment planning. Additionally, simulations utilizing three-dimensional(3D)printer models can enable realistic simulations of procedures such as intracranial stents and Woven EndoBridge placement. This approach is beneficial for shunt disorders such as arteriovenous malformations and dural arteriovenous fistulas, offering 3D visualization of shunt access routes and intuitive treatment strategy planning, even for beginners. Furthermore, it can be applied to procedures such as open surgical clipping and nidus resection, aiding in the selection of suitable clips and considerations for ideal resection based on nidus curvature. Simulations using CFD, CSM, and 3D printers are crucial for training surgeons and handling new devices. Harnessing medicine-engineering synergy is essential, and regulatory approval(insurance coverage)and appropriate commercialization of simulations are paramount for the future.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/cirurgia , Prótese Vascular , Stents , Software , Embolização Terapêutica/métodos , Resultado do Tratamento
18.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459863

RESUMO

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Estudos Retrospectivos
19.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38439540

RESUMO

OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) for aortic arch aneurysms is challenging because of anatomical restrictions and the presence of cervical branches. Revascularization of the cervical branch is required when conventional commercial stent grafts are used. TEVAR using fenestrated stent grafts (FSG) often does not require additional procedures to revascularize cervical branches. This study aimed to evaluate the features and initial and midterm outcomes of TEVAR using fenestrated stent grafts. METHODS: From April 2007 to December 2016, 101 consecutive patients underwent TEVAR using fenestrated stent grafts for distal aortic arch aneurysms at a single centre. Technical success, complications, freedom from aneurysm-related death, secondary intervention and aneurysm progression were retrospectively investigated. RESULTS: All the patients underwent TEVAR using fenestrated stent grafts. The 30-day mortality rate was zero. Cerebral infarction, access route problems and spinal cord injury occurred in 4, 3 and 2 patients, respectively. Each type of endoleak was observed in 38 of the 101 patients during the course of the study; 20/38 patients had minor type 1 endoleaks at the time of discharge. The endoleak disappeared in 2 patients and showed no significant change in 8 patients; however, the aneurysm expanded over time in 10 patients. Additional treatment was performed in 8 of the 10 patients with type 1 endoleaks and dilatation of the aneurysm. The rate of freedom from aneurysm-related death during the observation period was 98%. CONCLUSIONS: TEVAR with FSG is a simple procedure, with few complications. Additional treatment has been observed to reduce aneurysm-related deaths, even in patients with endoleaks and enlarged aneurysms. Based on this study, the outcomes of endovascular repair of aortic arch aneurysms using a fenestrated stent graft seem acceptable.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Correção Endovascular de Aneurisma , Endoleak/etiologia , Stents , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Fatores de Tempo , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia
20.
J Vasc Surg ; 79(3): 457-468.e2, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38453660

RESUMO

BACKGROUND: Fenestrated and branched endovascular aortic repair (F/BEVAR) of thoracoabdominal aortic aneurysms (TAAAs) has shown high technical success and low early mortality rates. Aneurysm extent has been reported as a factor affecting outcomes. This study aimed to assess the early and midterm follow-up outcomes of patients managed by F/BEVAR for types I through III TAAAs. METHODS: A single-center retrospective analysis was conducted, including data from consecutive, elective and urgent (symptomatic and ruptured cases), patients treated for types I through III TAAAs, between October 1, 2011, and October 1, 2022, using F/BEVAR. Degenerative and postdissection TAAAs were included. Patients received prophylactic cerebrospinal fluid drainage (CSFD), except those under therapeutic anticoagulation, those who were hemodynamically unstable, or those with failed CSFD application. When an initial thoracic endovascular aortic repair was performed, as part of a staged procedure, no CSFD was used. Later stages and nonstaged procedures were performed under CSFD. Thirty-day mortality and major adverse events (MAEs) were analyzed. Kaplan-Meier estimates were used for follow-up outcomes. RESULTS: F/BEVAR for types I through III TAAAs was performed in 209 patients (56.9% males; mean age, 69.6 ± 3.2 years; mean aneurysm diameter, 65.2 ± 6.2 mm); 29.2% type I, 57.9% type II, and 12.9% type III. Urgent repair was performed in 26.7% of patients (56 cases; 23 ruptured and 33 symptomatic cases) and 153 were treated electively. Thirty-two patients (15.3%) were classified as American Society of Anesthesiologists (ASA) class IV. CSFD was used in 91% and staged thoracic endovascular aortic repair was performed in 51.2% of patients. Technical success was 93.8% (96.7% in elective vs 94.6% in urgent cases; P = .92). Thirty-day mortality was 11.0% (4.6% in elective vs 28.5% in urgent cases; P < .001) and MAEs were recorded in 17.2% of cases (7.8% in elective vs 42.8% in urgent cases; P < .001). Spinal cord ischemia rate was 20.5% (17.6% in elective vs 28.7% in urgent cases; P = .08), whereas 2.9% of patients presented paraplegia (1.3% in elective and 7.1% in urgent cases; P = .03). The mean follow-up was 16 ± 5 months. Survival was 75.0% (standard error, 4.0%) and freedom from reintervention was 73.3% (standard error, 4.4%) at 36 months. ASA IV and urgent repair were detected as independent factors related to early mortality and MAE, whereas ruptured aneurysm status was related to spinal cord ischemia evolution. CONCLUSIONS: Endovascular repair for types I through III TAAAs provides encouraging early outcomes in terms of mortality, MAE, and paraplegia, especially in an elective setting. Setting of repair and baseline ASA score should be taken into consideration during decision-making.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Masculino , Humanos , Idoso , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Isquemia do Cordão Espinal/etiologia , Paraplegia/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA